Study Plan2110 Topo

Here are the 10 usual suspects (and what to do) when a 2110 plant misbehaves:


  1. PTP mismatch (domain/E2E–P2P/one-step–two-step)

  2. PTP not prioritized (QoS wrong)

  3. Inconsistent DSCP→queue mapping

  4. Transparent/Boundary clock misuse

  5. Multicast control broken (IGMP/PIM)

  6. MTU/fragmentation issues

  7. NIC/host not tuned for real-time
  8. 2022-7 mispaired or asymmetric
  9. SDP/NMOS inconsistencies
  10. Monitoring blind spots

Quick golden defaults:
One PTP domain (e.g., 127), P2P TC for small L2 or BC at agg/leaf for scale.
PTP = CS6 → LLQ; media = CS5/AF41; control lower.
IGMPv3 + SSM 232/8, MTU 9000, 2022-7 Red/Blue truly independent.
Validate WinOF-2/driver/firmware combos on NICs; verify with Wireshark and per-queue counters.

Host/NIC & servo

Must Match Checklist

domainNumber: identical across GM, BC/TC, endpoints.
delay mechanism: all E2E or all P2P.
timestamp style: all one-step or all two-step.

Profile: ST 2059 values (logSyncInterval, logAnnounceInterval, delay intervals) consistent.

Rule of thumb: faster (more negative) intervals improve tracking on noisy/asymmetric networks but add control traffic;
 pick rates your switches/NICs handle comfortably and give PTP strict QoS.

QoS

Congestion checks

Red/Blue issues

Timing


Grandmaster

On a switch/endpoint PTP status page:

Delay mismatch: plant is E2E, device is P2P (or vice-versa).
Domain mismatch (device on 0, plant on 127).
Host/NIC not timestamping: HW timestamping disabled or wrong NIC bound to the PTP client. Another time service (NTP/W32Time) fighting the PTP servo.

PTP


 

UPDATED
5/23/26